HZYN-1301 ASTM D445 Viscometer Cinematig Olew Awtomatig
Viscometer Cinematig Olew HZYN-1301 Bath Astm D445
Amlinelliad
This Kinematic Viscometer is designed and manufactured specially according to the national standard "GB265 – 88 Determination of kinematic viscosity of petroleum products" . It's suitable to determine kinematic viscosity of liquid petroleum products. This apparatus has the function of timing of the trial sample movement and can calculate the final result of kinematic viscosity. This method is suitable to determine kinematic viscosity of liquid petroleum products ( It refers to Newtonian liquids ), and its unit is m2/s. Generally in actual utilization, the unit is mm2/s. The dynamic viscosity is equal with the result which use kinematic viscosity to multiply the density of the liquid. By this method, it can determine the time that the liquid with the certain volume flows past the calibrated glass capillary viscometer under the gravity in the certain stable temperature and the value that the constant value of capillary in the viscometer multiplies the flowing time, that is , the determined kinematic viscosity of liquid at the temperature. At the temperature, the value that kinematic viscosity multiplies the density of the liquid in the same temperature is the dynamic viscosity at the temperature.

Data Tech
Tyllau bath hylif | 4 |
Ystod i reoli'r tymheredd | Indoor temperature—120 degree |
Cywirdeb i reoli'r tymheredd | Room temperature -120 degree Less than or equal to ±0.1 degree |
Tymheredd ystafell | -40 degree Less than or equal to ±0.2 degree |
ffynhonnell pŵer mewnbwn | AC220V±10V, 50HZ |
Pŵer gwresogi | 1000W |
Amseroedd prawf | O 1 i 6 gwaith, yn gallu addasu. |





Amodau Defnyddio
(1) Tymheredd amgylcheddol: 0 gradd -40 gradd
(2) Lleithder cymharol:<>
Sylw
(1). Pan nad oes dŵr y tu mewn i'r acwariwm, mae'n gwahardd pŵer ymlaen.
(2). In the liquid of the bathtub, there can't be impurities and floating materials in order to avoid to block the test holes. For the new bath liquid , it often appears bubbles when heating, which will affect the test, especially when it appears bubbles in the test holes, it will have the most serious affect. Please loose the capillary to check if there is bubble in the test holes. If it appears, please use the hose to blow in order to get rid of the bubbles or use the clean the toothbrush to wash off the bubbles.
(3). Cyn i ni ddefnyddio'r offer, rhaid inni sicrhau'r daearu dibynadwy.
(4). Pan fyddwn yn-ailgychwyn y cyfarpar, mae angen i'r cyfnod defnydd fod yn fwy na 15 munud. Ac mae'r cyfarpar yn cael ei gychwyn yn y cyflwr bath oer, ac mae angen ei ddefnyddio ar ôl 45 munud.
(5). When we rectify the temperature with the full-immersion thermometer, the effective scale of the thermometer can't be exposed to the liquid level of the constant temperature bath.
(6). Gwahardd storio neu ddefnyddio'r cyfarpar yn yr amgylchedd gwlyb gyda'r nwy cyrydol.
(7). Pan fyddwn yn clipio'r capilari, nodwch uchder yr agoriad uchaf ac osgoi mynd i mewn i ddŵr yn y tiwb profi.
(8). Ar ôl ei ddefnyddio am gyfnod neu pan fyddwn yn canfod bod y mesuriad lefel olew yn ansensitif, dylem lanhau'r tyllau prawf yn y clip prawf mewn pryd.
(9). During using the apparatus, if appears fault, you should invite the professionals to repair and contact with us in time. If it's quality problem, we can offer the gratuitous warranty within one year.
(10). Ar gyfer y ffynhonnell pŵer, rhaid i chi gadw'r daearu da.



Tagiau poblogaidd: HZYN-1301 ASTM D445 Viscometer Cinematig Olew Awtomatig, Tsieina, cyflenwyr, gweithgynhyrchwyr, pris, ar werth, viscometer cinematig, viscometer cinematig ar gyfer cynhyrchion petrolewm, viscometer cinematig awtomatig cludadwy, Viscometer Cinematig Bath, viscometer cinematig gyda bath digidol, Viscometer Cinematig Olew Crai ISO3104 , hzyn-1301, mesurydd gludedd cinetig, prawf gludedd cinematig bitwmen, Viscometer Cinematig Olew Inswleiddio, kinematicviscometer, profwr gludedd olew injan
Anfon ymchwiliad